NetCAN Plus 110 Mini

Converter Ethernet to CAN Bus

Vscom NetCAN+ (Plus) 110 Mini, a small CAN Bus Gateway for Ethernet/WLAN/Internet
Features
Specifications
Ordering Information
Drivers & Documentation
Datasheet
Inquiry this product
View Larger Image

The NetCAN Plus series consists of smart Ethernet to CAN-Bus gateways, making the integration of CAN-Busses into existing Ethernet network topologies possible. Higher layer protocols, such as CANopen, can be assembled using the available development tools for complex automation control applications. Properties such as very low power consumption (2W typical), an extended temperature range (−20C - +65°C) and wide power supply (7 - 30V DC) make it an ideal system for industrial automation.

Operation Modes

NetCAN Plus series supports three operating modes: TCP Raw Server, CAN Bridge and Driver Mode. With the TCP Raw Server the communication is handled directly via IP address and port number. The CAN Bridge connects two CAN-Busses over an Ethernet/WLAN/VPN tunnel using two NetCAN Plus devices (read more …). The Driver Mode requires the installation of a virtual com-port driver, which makes the network fully transparent to the application.

Usage Options

NetCAN Plus provides various software tools to interface each level of the user applications:

  • The ASCII conversion protocol is handy in developing and testing any CAN-BUS configuration. Users simply connect directly via Telnet, and have a simple way to talk to the CAN controller. The device can also be used to manually transmit and receive CAN frames.
  • Applications programmed by users should use the VScan API library (DLL), which handles the communication and ASCII conversion for the CAN frames in a transparent manner. In their applications, programmers have to handle only the CAN frames and status information, without taking care of the ASCII conversion. The VScan API is supported in C/C++, C#, VB.NET, Delphi and LabVIEW. Under Linux SocketCAN can be used as alternative to VScan API. All VScom CAN devices support the standard Serial Line CAN (slcan) driver.
  • The NetCAN Plus series also supports CANFestival, an Open Source CANopen Framework. CANopen is a CAN-based higher layer protocol that is used in various application fields to unburden the developer from dealing with CAN-specific details. CANopen provides standardised communication objects for real-time data, configuration data as well as network management data.
  • The SAE J1939 protocol, resting upon the CAN hardware layer, is commonly used in the commercial vehicle area. A lot of other modern protocols are based on it, like NME200, ISOBUS, MilCAN or FMS. Vscom’s J1939 API also includes support for the so called Transport Protocol, which will bypass the limit of 8 data bytes per message. It's available on J1939-enabled devices. Supports Windows, Linux, .NET   read more …

Secure Remote Access

For the NetCAN Plus series there is a software option using the viaVPN Cloud system (www.viaVPN.com), which can be remotely accessed and monitored over the Internet. viaVPN provides secure and strongly encrypted access, without the need for any reconfiguration of existing firewalls. In case a customer's firmware/application is accessible via Ethernet or Wifi — as for example via a web interface or Telnet/SSH connection — viaVPN extends the access over internet by a protected VPN tunnel. If the CAN-Bus port is not occupied by local access, also remote operation over Internet is possible.


Keywords: CAN Bus automotive CAN 2.0A CAN 2.0B ISO 11898 CANopen CANFestival Ethernet WLAN Bridge-Mode NET-CAN+ NETCAN+ Plus

Connect 2 separate CAN Bus lines by network bridge, adapter for PC. Some users spell NET-CAN as NETCAN. Also NET-CAN Plus is referred to as NET-CAN+.
Features

  • Phased Out, no longer available
  • Ultra small metal case, 1W power consumption
  • Connects CAN-Bus via LAN to PC
  • Supports CAN 2.0A / 2.0B at 1MBit/s
  • LAN 100/10 Ethernet auto-detect
  • CANopen supported by CANFestival
  • SAE J1939 protocol supported by VScom’s J1939 API
  • Bridge mode to tunnel 2 CAN-Busses
  • Easy-to-use DLL Library for CAN bus access
  • Remote Frame support, Listen only mode
  • OS supported: Windows, Linux, Windows CE
  • Development: C/C++, C#, VB.NET, LabVIEW, Delphi
  • Secure Remote Access by viaVPN Cloud (optional)
  • Supports Bosch Busmaster Debugging
  • 16kV ESD surge protected
  • Wide range power supply 9 - 30V
  • Extended temperature −20C - +65°C
  • DIN-Rail mountable (optional)

Back to Top  
Specifications
Ethernet Interface
  Speed/Type
100Mbps/10Mbps Auto-detecting
  Connector
RJ45 (8P8C) 8 pin
  LEDs
Power, Ready, Ethernet Link / Speed
Back to Top  
CAN Bus
  No. of Ports/Type
1 × CAN Bus
  Connector
DB9 male
  Protection
16kV ESD surge protection
  Signals
CAN_H, CAN_L, CAN_GND
  Speed
CAN 2.0A / 2.0B 1Mbit/s
  LED
CAN-Data, CAN-Error
Back to Top  
Operating Modes
  TCP Raw Server
Raw Data transfer over TCP/IP. Accepts multiple incoming connections.
  CAN Bridge
CAN networks are connected via TCP/IP (WLAN or Ethernet). A client connects to a Server, CAN frames received on one network are repeated on the other network.
  Virtual Com Mode
Driver for virtual COM port available for
Windows 2000, XP up to Windows 10
Windows Server 2000 up to 2008 R2
Back to Top  
Software
  VSCAN API
Unified API for control of all VScom CAN-Adapters.
Supported OS: Windows, CE, Linux (x86, x86-64, ARM) targets.
Supported Dev.Env: C/C++, C#, VB.NET, Delphi and LabVIEW.
  Linux OS
Supports SocketCAN (slcan driver) since kernel 2.6.38+
Also see this FAQ
  CANopen
Open source CANfestival framework fully implements CANopen functionality.
  SAE J1939
Automotive protocol suite supported by Vscom’s J1939 API.
Supports NME200, ISOBUS, MilCAN and FMS protocols for Windows, Linux and .NET
  Monitoring Tools
Bosch BUSMASTER v3.2.0 and above
  Data Coding
ASCII format
  CAN Modes
Standard Mode
Normal operation on CAN bus
Listen Mode
Passive receive of CAN Frames, neither ACK bits nor Error Frames are sent
Self Reception (Echo Mode)
For testing: Transmitted Frames are also received by the adapter
Back to Top  
Installation & Configuration
  UPnP
With Network discovery enabled NetCom Plus servers announce their presence via UPnP making their IP visible.
  Configuration
NetCom Manager to find and configure NetCANs in network
Driver Panels, WEB Browser, Serial Console, Telnet, SNMP
  Firmware Update
via WEB Browser
  Firewall
Virtual-COM mode works through firewalls
Back to Top  
Security
  Password Protection
for all available configuration options e.g. via WEB-Browser
  Secure Server
create openVPN™ tunnels, for encrypted transmission of all serial and configuration data using high security SSL/TLS standards.
Back to Top  
viaVPN Remote Access (option)
  Connect via Internet
viaVPN technology provides easy and secure access to remotely installed NetCom Plus servers for their configuration or for connecting their virtual COM ports through Internet. With the viaVPN option the NetCom Plus servers are no more limited to only work inside of a local network.
  Security
All communications use openVPN-tunnels encrypted by SSL/TLS and AES-256 standards.
  Firewall friendly
No Reconfiguration of firewalls is required for viaVPN remote access.
Back to Top  
Power Requirements
  Input Voltage
9 - 30V DC
  Power Consumption
80mA @ 12V, 1W max
  Connector
2-pin Terminal Block
Back to Top  
Housing and Mounting
  Case
0.8mm sheet metal
  Weight
w/o box 0.10kg; w/h box 0.20g
  Dimensions
50×72×22 mm³ (W×L×H) Case
72×72×22 mm³ (W×L×H) with mounting wings
  Packaged
85×122×55 mm³
  Mounting
DIN-Rail (optional)
Wall mount
Back to Top  
Environmental Data
  Operating Temp
−20°C - 65°C
  Storage Temp
−20°C – 85°C
  Ambient Humidity
5-95% non condensing
Back to Top  
Standards
  Declarations
CE, FCC
  EMI
EN 55022 Class B
EN 61000-3-2: Limits of harmonic current emissions
EN 61000-3-3: Limitation of voltage changes
47 CFR FCC Part 15 Subpart B
  EMS (EN 55024)
EN 61000-4-3: Radiated RFI
EN 61000-4-4: Electrical Fast Transient
EN 61000-4-5: Surge
EN 61000-4-6: Induced RFI
EN 61000-4-8: Power Frequency Magnetic Field
EN 61000-4-11: Power supply dips
  ESD
IEC 61000-4-2 4kV contact 8kV air for
CAN Bus Port
Ethernet
DC Power connector
Back to Top  
MTBF (Mean Time Between Failures)
  MTBF
available soon
  Standard
Telcordia (Bellcore) Standard; RelCalc. 5.0 BELL-7
Back to Top  
Warranty
  Warranty Period
2 years
Back to Top  
Open Source Software
  Licenses
This product uses open source software to fulfill part of its functions. Licenses for the open source software are granted under the GNU General Public License in various versions. For details about those see the information in the firmware download and visionsystems.de/opensource
Back to Top  
Ordering Information
  419
NetCAN Plus 110 Mini
Back to Top  
Options
  6031
Power adapter 110-230V AC to 12V @1A, DC, EU plug
  6034
Power adapter 110-230V AC to 12V @1A, DC, US plug
  6679
Activate option viaVPN for secure remote access over Internet
  411
Purchase-time option to enable protocol J1939
  662
DK 35A Plastic DIN-Rail mounting kit (use with 6693)
  6064
DB9F-to-TB/10 for CAN bus free wiring option
Back to Top  
Packaging
  Packing list
NetCAN Plus 110 MINI
Terminal block for Power Supply
Back to Top  
You can purchase VSCOM's products easily from a wide variety of leading technology distributors or partners. Please call us or contact us by mail to find the best ordering method for your needs.
 
  * Specifications are subject to change without notice.
  * All the trademarks and brands are property of their rightful owners.

About VSCOM | Impressum | Contact Us | Term & Conditions | Privacy Policy© 1993-2023 VS Vision Systems GmbH. All rights reserved.