Home | VSCOM Info | Partner Login | Contact | Language
VSCOM Home
  Search :

Products >> Network to Serial >> ModBus Gateway

ModGate Plus 413
(ModGate 413)

4x RS232/422/485 by Modbus for LAN or WLAN

VScom NetCom+ (Plus) 411/413, a quad port Serial Device Server for Ethernet/TCP to RS232/422/485
Features
Specifications
Ordering Information
Drivers & Documentation
Datasheet
Inquiry this product
View Larger Image
  BUY

The ModGate Plus is an easy to use Gateway between Modbus/TCP on Ethernet or WLAN, Modbus/RTU and Modbus/ASCII. ModGate Plus 413 connects four Modbus serial lines to a network running TCP/IP. It can also connect Modbus/RTU and Modbus/ASCII busses.

Hardware Characteristics

With its metal case, a wide temperature range and a flexible DC power supply, the ModGate Plus classifies as an industrial-strength device. The product line is based on a state-of-the-art RISC processor, providing a cost-effective design and low power consumption.
The serial ports can be configured to physically use RS232, RS422 or RS485, allowing the utilisation of multiple Modbus Slaves on a single serial line.

Operational Benefits

The ModGate Plus devices make Modbus operations independent of distance and OS platforms; they can be accessed and controlled via Internet and VPN connections.

The messages received on the network are sent to the destination serial line; replies from serial port are sent back across the network and vice versa. A ModGate Plus device functions automatically, whether a Modbus Master is on a serial port or on the TCP/IP network.

Modbus Master Multiplexing is implemented as an extension to the standard: Several Masters can connect to ModGate Plus using Modbus/TCP whilst slaves on serial lines may answer requests from multiple Masters.

The configuration of ModGate Plus is done via browser. The user interface is based on modern web technologies to allow for an easy navigation through the configuration options provided. Furthermore, UPnP provides a simple and standardized way to find the Gateway in the network.

ModGate Plus devices can be ordered with an embedded module for WLAN 802.11b/g/n. A ModGate Plus 413 may be ordered as POE device, with additional power supply via Power-over-Ethernet complying with 802.3af (Class 0).


Keywords: Serial to Ethernet converter, RS232, Device Server, Serial Port Server, RS232 zu Ethernet LAN Adapter, TCP/IP, Com Port Redirector, Power over Ethernet, USB 2.0

A Serial Device Server for TCP/IP on Ethernet, WLAN and Internet, RS232/422/485 as Com Ports in Windows. USB 2.0 allows WLAN function. NetCom+ is also written as NetCom Plus. 4-Port devices: NetCom Plus 411 and NetCom Plus 413.
Features

  • Converts between Modbus/RTU, Modbus/ASCII and Modbus/TCP over Ethernet, WLAN or Internet
  • LAN 10/100 Fast Ethernet
  • Configuration over Web interface
  • Supports Modbus Master Multiplexing
  • Supports TCP/IP, DHCP, ICMP, HTTP, DNS
  • RS232/422/485 interface selected by Software
  • Optional: Wireless network IEEE 802.11b/g/n

Back to Top  
Specifications
Ethernet Interface
  Speed/Type
100Mbps/10Mbps Auto-detecting
  Connector
RJ45 (8P8C) 8 pin
  LEDs
Power, WLAN, Ready, Ethernet Link / Speed
Back to Top  
Serial Interface
  No. of Ports/Type
4 × RS232/422/485 selected by software
  Connector
DB-9 male
  Protection
16kV ESD surge protection
  Operating Modes
RS232
RS422 full duplex              (120Ω on/off)
RS485 4 wire, full duplex    (120Ω on/off)
RS485 2 wire, half duplex   (120Ω on/off)
  Configuration
Software sets operating mode and RS422/485 termination
No High/Low biasing resistors needed
  Signals
RS232: TxD,RxD, RTS,CTS, DTR,DSR, DCD, GND
RS422: Tx+/-, Rx+/-, GND
RS485 4 wire: Tx+/-, Rx+/-, GND
RS485 2 wire: Data+/-, GND
  RS485 Data Direction control
ARTc (Automatic Receive Transmit control)
  Data bits
7, 8
  Stop bits
1, 2
  Parity
None, Even, Odd
  Baudrate
ModBus: up to 115.2 kbps
RS232: 200 bps to 921.6/1000 kbps (physical)
RS422/485: 200 bps to 3.7Mbps (physical)
  LEDs
TxD/RxD for each port
Back to Top  
Software
  Installation
DIP switches set the device to DHCP or a defined fixed IP Address to be contacted via WEB Browser
  Operating mode
Promiscous Mode
Messages received from the network are sent to the defined serial port, messages from the serial port are sent to the connected network host. (Circuit Switching)
Direct Mapping Mode
Received messages are scanned for their target address. This address is found in the mapping table, the message is sent to the defined connection. (Packet Switching)
  Network Protocols
Modbus/TCP, TCP/IP, DHCP, ICMP, HTTP, DNS, UDP, UPnP/SSDP
  Serial Protocols
Modbus/RTU and Modbus/ASCII
  Modbus Master Multiplexing
An extension to the standard. Slaves on serial lines may answer requests from multiple masters. The masters connect to ModGate Plus by Modbus/TCP.
  Configuration
Configuration over WEB Browser
  Detection
Announces presence in the network via Universal Plug and Play (UPnP) protocol
  DNS
Domain Name Server support
  Firmware
Firmware update over WEB Browser
  Security
Webinterface is password protected. The password can be changed in the Webinterface.
  USB 2.0
for logging/debugging
Back to Top  
Wireless interface (option)
  Standards
2.4GHz Radio, supports IEEE Std. 802.11b/g/n
  WLAN Modes
Access Point (AP) or Client (Station)
  TX Power
802.11b:
Typ. 15.5dBm ±1.5 dBm @ 1Mbps (DSSS)
Typ. 15.5dBm ±1.5 dBm @ 11Mbps (OFDM)
802.11g:
Typ. 15.6dBm ±1.5 dBm @ 6Mbps (CCK)
Typ. 13.5dBm ±1.5 dBm @ 54Mbps (OFDM)
802.11n:
Typ. 13.4dBm ±1.5 dBm @ 6.5Mbps (OFDM)
Typ. 13.3dBm ±1.5 dBm @ 150 Mbps(OFDM)
  RX Sensitivity
802.11b:
-95.6dBm @ 1Mbps, -88dBm @ 11Mbps
802.11g:
-91.3dBm @ 6Mbps, -74.2dBm @ 54 Mbps
802.11n:
-88.8dBm @ 6.5Mbps (20 MHz), -72dBm @ 72.2Mbps (20 MHz)
  Transmission Rate
802.11b: 11Mbps
802.11g: 6 to 54Mbps
802.11n: 6.5 to 150Mbps
  Transmission Distance
Up to 100m in open areas
  Wireless security
WEP
WPA
WPA2
WPA2-Enterprise (IEEE 802.1X/RADIUS)
  Antenna Connector
RP (Reverse-Polarity) SMA
Back to Top  
Power Requirements
  Input Voltage
9 - 54V DC
  Power Consumption
0.3A @ 12V, 4W max
  Connector
3-pin Terminal Block
  Power over Ethernet
PoE Class 0 Device, IEEE 802.3.af, 8W max.
Automatic switch between PoE and local power
for POE Version only
Back to Top  
Housing and Mounting
  Case
0.8mm sheet metal
  Weight
w/o box 0.9kg; w/h box 1.35kg
  Dimensions
196×147×44 mm³ (W×L×H)
  Packaged
310×192×60 mm³
  Mounting
19-inch Rack
Wall mount
Back to Top  
Environmental Data
  Operating Temp
−20°C - 65°C
  Storage Temp
−20°C – 85°C
  Ambient Humidity
5-95% non condensing
Back to Top  
Standards
  Declarations
CE, FCC
  EMI
EN 55022 Class B
EN 61000-3-2: Limits of harmonic current emissions
EN 61000-3-3: Limitation of voltage changes
47 CFR FCC Part 15 Subpart B
  EMS (EN 55024)
EN 61000-4-3: Radiated RFI
EN 61000-4-4: Electrical Fast Transient
EN 61000-4-5: Surge
EN 61000-4-6: Induced RFI
EN 61000-4-8: Power Frequency Magnetic Field
EN 61000-4-11: Power supply dips
  ESD
EN 61000-4-2 4kV contact 8kV air for
Serial Ports
USB
Ethernet
DC Power connector
Back to Top  
MTBF (Mean Time Between Failures)
  MTBF
24.8 Years @ 25°C
9.9 Years @ 45°C
  Standard
Telcordia (Bellcore) Standard; RelCalc. 5.0 BELL-7
Back to Top  
Warranty
  Warranty Period
2 years
Back to Top  
Open Source Software
  Licenses
This product uses open source software to fulfill part of its functions. Licenses for the open source software are granted under the GNU General Public License in various versions. For details about those see the information in the firmware download and visionsystems.de/opensource
Back to Top  
Ordering Information
  6730
ModGate Plus 413 (4x RS232/422/485)
Back to Top  
Options
  6031
Power adapter 110-230V AC to 12V @1A, DC, EU plug
  6034
Power adapter 110-230V AC to 12V @1A, DC, US plug
  on Request
Option POE, 802.3af (Class 0)
Power-over-Ethernet alternative supply
  6689
WLAN Kit internal
internal module 802.11b/g/n, pigtail and antenna
Purchase time option, not for later retrofitting
  6064
DB9F-to-TB/10 for RS422/485 free wiring option
  6061
DB9F-to-RJ45 for changing from DB9 to CAT5 wiring
(Optimised for RS422/485 operating modes)
  6062
RJ45-to-DB9M for changing back from CAT5 to DB9 wiring
(Required to match the DB9 pinout at USB-COM Plus Mini)
  661
Serial Null-Modem adapter 9PF-9PF, change male to female
Back to Top  
Packaging
  Packing list
ModGate Plus 413
Mounting brackets for 19-inch rack
Wall mount plates
Terminal block for Power Supply
Back to Top  
You can purchase VSCOM's products easily from a wide variety of leading technology distributors or partners. Please call us or contact us by mail to find the best ordering method for your needs.
 
  * Specifications are subject to change without notice.
  * All the trademarks and brands are property of their rightful owners.

About VSCOM | Impressum | Contact Us | Term & Conditions | Privacy Policy© 1993-2023 VS Vision Systems GmbH. All rights reserved.